Indianapolis, Indiana

This project included the relocation of 30L engines, 4000hp prime mover component testing equipment and connection to associated utilities.  MNA designed Class 1  test cells with up to 60L hp engine set-ups.  Design includes: ventilation, combustion air, scavenge exhaust air, engine exhaust, diesel exhaust fluid, lube oil, compressed air, bed plates, inertia mass, cranes, heating and cooling, power, lighting, grounding, data gathering, fire suppression, fire alarm, and process cooling.  In addition, the facility up-fit included installation of testing equipment.